iSpecLIBS-OEM-A Microscopic LIBS Elemental Analyzer

Microscopic LIBS elemental analysis with extended-depth-of-field imaging, precise point selection, depth profiling, and automated multi-point mapping.

Features

  • Direct analysis with minimal material removal; no conductive coating or vacuum required
  • Highly localized elemental analysis of micron-scale regions
  • Broad elemental coverage, including light elements such as C, H, O, N, Li, Be, and B
  • Micrometer-scale depth profiling and three-dimensional elemental mapping
  • Automatic peak detection, spectral matching, and real-time concentration prediction
  • Quantitative calibration using peak height, peak area, and spectral intensity ratios

Microscopic Elemental Analysis

The LiSen Optics iSpecLIBS-OEM-A combines high-resolution microscopy with laser-induced breakdown spectroscopy (LIBS) for rapid elemental analysis of precisely selected areas. A tightly focused pulsed laser creates a microplasma on the sample. The system analyzes the emitted spectrum to identify and quantify the elements at the point shown in the microscope image.

This dedicated microscopic LIBS module integrates a pulsed laser, a high-resolution spectrometer, excitation and collection optics, microscopic imaging, trigger-delay control, and analysis software. It is compatible with Olympus DSX1000 and DSX2000 microscopes and other digital microscopes with extended depth of field.

The system supports material identification, classification, and composition analysis in metals, battery materials, food, pharmaceuticals, automotive components, and other advanced materials.

Technical Specifications

Technical Specifications
Parameter iSpecLIBS-OEM-A
Product Image LiSen Optics iSpecLIBS-OEM-A microscopic LIBS elemental analyzer with laptop
Elemental Range Broad coverage of alloy-related elements, including Fe, Al, Cu, Mg, Ni, Pb, Cd, and selected nonmetals such as C
Concentration Range ≥0.1% (dependent on element, matrix, and measurement conditions)
Analysis Time <1 s
Analysis Modes Semi-quantitative and quantitative analysis
Dual-Channel Spectrometer CH1: 180–430 nm, resolution ≤0.3 nm; CH2: 365–545 nm, resolution ≤0.25 nm (custom wavelength ranges available)
Laser 1064 nm; >10 mJ/pulse; 10 Hz; <3 ns pulse width; pulse-energy stability <3%
Sample Types Metal grades and alloys; also suitable for minerals, rocks, ceramics, semiconductor materials, fossil fuels, soils, and solid composites
Analysis Spot Size 1064 nm: <80 µm; 532 nm: <50 µm; 355 nm: <25 µm
Working Distance 50 mm
Beam Orientation Vertical
Measurement Geometry At the focal plane
Laser Safety No ionizing radiation; no radioactive-source licensing required
Operating Temperature 15–35 °C
Supported Use Cases Metal grade identification, laboratory research, LIBS demonstrations, and microscope integration; built-in forced-air cooling
Communications USB/TCP

Microscope Integration

Microscope integration design for the iSpecLIBS-OEM-A module
Microscope integration design
Close-up of the microscope objective and sample positioning assembly
Microscope objective and sample positioning assembly

LIBS Operating Principle

A focused laser pulse removes a small amount of material and generates a plasma. Collection optics guide the emitted light to the spectrometer, where characteristic spectral lines identify the elements present. Microscopic imaging allows the operator to select a small region of interest before analysis.

LIBS optical path from laser excitation at the sample to spectral detection
LIBS operating principle

Typical LIBS Detection Limits

LIBS can detect nearly all elements, including light elements such as C, H, O, N, Li, Be, and B. Typical detection limits for many elements are in the 10–100 ppm range. The following values describe representative LIBS detection limits:

  • Li, Be, B, Na, Mg, Al, K, and Ca: approximately 10 ppm (0.001%).
  • Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, and Mo: approximately 100 ppm (0.01%).
  • C, N, O, P, and Si: approximately 200 ppm (0.02%).
  • F, Cl, Br, and S: approximately 0.5%.

Actual detection limits vary with the element, sample matrix, and measurement conditions. The model-specific concentration range is listed in the technical specifications above.

Periodic table showing the original LIBS detection-limit categories
Typical LIBS detection limits across the periodic table

LIBS Spectral Acquisition and Analysis Software

The software provides automatic peak detection, spectral matching, real-time concentration prediction, and quantitative calibration using peak height, peak area, and spectral intensity ratios. Available functions vary between the iSpecLIBS-STD Basic and iSpecLIBS-SCI Professional editions.

Software Edition Comparison
Software Function iSpecLIBS-STD (Basic) iSpecLIBS-SCI (Professional)
LIBS spectral data acquisition Yes Yes
Pulse trigger-delay generator control Yes Yes
Dual-laser aiming, image-based focus control, and synchronized 3-axis stage control No Yes
Camera image acquisition and display No Yes
User-defined spectrometer integration time, number of averages, and trigger delay Yes Yes
User-defined laser pulse energy and repetition rate Yes Yes
Real-time autofocus and fixed-focus operation No Yes
Preview, save, and analyze spectra from multiple sample types Yes Yes
Automatic peak finding and element identification with real-time comparison to reference lines Yes No
Position-resolved mapping with stepped scanning of channel settings, integration time, trigger delay, and laser energy; supports up to 10,000 acquisition points No Yes
Spectral preprocessing, including background correction, baseline correction, and peak-intensity normalization No Yes
Environmental and matrix-effect correction to improve quantitative reliability No Yes
Simultaneous multi-element analysis with spectral deconvolution for overlapping emission lines No Yes
Custom model training and calibration with linear or polynomial fitting, peak ratios, and peak-area calculations No Yes
Results reporting and validation, including concentrations, uncertainty estimates, and statistical significance No Yes
Interfaces for machine-learning and deep-learning algorithms to improve complex-sample identification and quantitation No Yes
Image-based region segmentation, autofocus, automated point selection, qualitative and quantitative analysis, and elemental concentration mapping No Yes
iSpecLIBS-SCI Professional software with microscope views, LIBS spectra, and a 3D elemental map
iSpecLIBS-SCI Professional LIBS spectral analysis software

Mineral Identification and Elemental Mapping

The Professional software examples show reflectance hyperspectral mineral identification, AI-based mineral mapping, three-dimensional elemental concentration mapping, and two-dimensional elemental distribution visualization.

Reflectance hyperspectral spectrum and mineral identification results
Reflectance hyperspectral mineral identification
AI-based mineral mapping with original spectral and elemental analysis data
AI-based mineral mapping
Three-dimensional elemental concentration map beside the original LIBS spectrum
3D elemental concentration mapping
Two-dimensional elemental distribution visualization with original concentration values
2D elemental distribution visualization

The software screenshots retain the original measurement results. Some fine result labels and status text remain in the source language because the supplied images are too small for reliable translation.

Applications

Electronic Contamination Analysis

High-magnification imaging and rapid elemental analysis help investigate printed circuit boards, connectors, and other precision electronic components. The microscope reveals connector pins, solder joints, and surface contaminants, while LIBS spectra identify their elemental composition and help engineers determine possible sources of contamination.

Microscope view of electronic connector pins and solder joints
Inspection of connector pins and solder joints
Printed circuit board used to illustrate electronic component analysis
Printed circuit board analysis

Layer-by-Layer Elemental Analysis

Repeated laser pulses form a controlled microcrater through coatings and intermediate layers to the substrate. This enables elemental characterization from the surface into the material. Samples with coatings or oil films can be analyzed directly without pretreatment.

Successive laser pulses penetrating a coating, an intermediate layer, and the substrate
Layer-by-layer laser ablation
Microcrater diameter and depth diagram with laser ablation crater photographs
Microcrater geometry and laser ablation examples

Multi-Point Elemental Analysis

Automated multi-position analysis can characterize a substrate and attached materials, investigate several contaminants on one surface, or compare separate regions of interest. The system analyzes the selected locations in a single workflow, reducing repositioning and repetitive operations while improving throughput, consistency, and accuracy.

Elemental distribution and spatially resolved sample images supplied in the product documentation
Examples of spatially resolved elemental analysis

Explore the LIBS elemental analyzer range or contact LiSen Optics to discuss microscope integration and your measurement requirements.